Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Med Device ; 14(1): 011109, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32328212

RESUMEN

Three-dimensional (3D) printing may be a solution to shortages of equipment and spare parts in the healthcare sector of low- and middle-income countries (LMICs). Polylactic acid (PLA) for 3D printing is widely available and biocompatible, but there is a gap in knowledge concerning its compatibility with chemical disinfectants. In this study, 3D-printed PLA tensile samples were created with six different printer settings. Each of these six batches consisted of five sets with five or six samples. The first set remained untreated, the others were soaked in Cidex OPA or in a chlorine solution. These were applied for seven consecutive days or in 25 short cycles. All samples were weighed before and after treatment and subjected to a tensile test. Results showed that a third of the treatments led to an increase of the median weight with a maximum of 8.3%, however, the samples with the best surface quality did not change. The median strength increase was 12.5% and the largest decrease was 8.8%. The median stiffness decreased 3.6% in one set and increased in three others up to 13.6%. When 3D printing PLA medical tools, surface porosity must be minimized to prevent transfer of disinfectants to people. The wide variability of mechanical properties due to 3D printing itself and as a consequence of disinfection must be considered when designing medical tools by selecting appropriate printer settings. If these conditions are met, reusing 3D-printed PLA medical tools seems safe from a mechanical point of view.

2.
J Biomed Opt ; 23(11): 1-10, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30447060

RESUMEN

In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. However, because tumor surgeries are often performed with an electrosurgical knife, the effect of a coagulated tissue layer on DRS measurements must be taken into account. It is evaluated whether real-time DRS measurements obtained with a photonic electrosurgical knife could provide useful information of tissue properties also when tissue is coagulated and cut. The size of the coagulated area is determined and the effect of its presence on DR spectra is studied using ex vivo porcine adipose and muscle tissue. A coagulated tissue layer with a depth of 0.1 to 0.4 mm is observed after coagulating muscle with an electrosurgical knife. The results show that the effect of coagulating adipose tissue is negligible. Using the fat/water ratio's calculated from the measured spectra of the photonic electrosurgical knife, it was possible to determine the distance from the instrument tip to a tissue transition during cutting. In conclusion, the photonic electrosurgical knife can determine tissue properties of coagulated and cut tissue and has, therefore, the potential to provide real-time feedback about the presence of breast tumor margins during cutting, helping surgeons to establish negative margins and improve patient outcome.


Asunto(s)
Neoplasias de la Mama , Coagulación con Láser/métodos , Análisis Espectral/métodos , Cirugía Asistida por Computador/métodos , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/cirugía , Algoritmos , Animales , Mama/diagnóstico por imagen , Mama/cirugía , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Diseño de Equipo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Biológicos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/cirugía , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...